- Plug the red test probe into the meter socket marked VΩmA. Plug the black test probe into the meter socket marked COM. Rotate the function selector knob to any setting other than OFF.If the display does not turn on, or if you see the BAT indicator on the display, replace the meter’s internal 9.
- Gdt 295a Manual - www.transactionbooks.com. Operators instruction manuals gardner bender cj5 manual gdt-292a user manual 500 manual gdt 294a manual indiana chauffeur license guide gb instruments gdt-292a instruction manual tomos outboard manual gx25 honda 4 stroke owners manual 8 hp service manual vitamix 5200 manual.
- May 08, 2017 GB Electrical GMT-18A Compact 18 Range Analog Tester. The instruction manual says 'approx 109mm X 70mm X 33mm'. That converts to 4.3 X 2.8 X 1.3 inches, about what I measure with a ruler. With leads inserted, the 1.3' dimension becomes about 1.5'. The test leads do take up space beyond that occupied by the meter but not as much as implied.
Answer key directed reading section weather instruments answer key njatc code and texas instruments calculators pdf texas instruments ti 84 manual gb instruments gdt 11 user manual instruments of marketing communications mix surgical.manual/g-l-l-2000-rustic-guitars-owners-manual.pdf 2015-03-25. 3932 user reviews, Gb Gdt 292a Manual Verified Download Gb Gdt 292a Manual.PDF. Gdt 295a user manual documents Gdt 295a User Manual. Description Date Size Speed Downloads; gdt 295a user manual - Full Version by KMGoodwin 2015-04-25: 2,899.45 KB: 452: gdt 295a user manual Gb instruments multimeter gdt 11 manual Buy Gb Instruments Gdt 295a.
Digital Multimeter image by TekinT from Fotolia.com
Gardner Bender’s GDT-11 is a handheld digital multimeter with a 3 1/2-digit liquid crystal numeric display. The meter measures volts for direct and alternating currents, resistance and DC current. In addition, the unit has a diode check feature.
Preparing Meter and Battery
Snap the battery clip onto one of the batteries; set the battery aside for measuring voltage and current.
Plug the red test probe into the meter socket marked VΩmA.
Plug the black test probe into the meter socket marked COM.
Rotate the function selector knob to any setting other than OFF. If the display does not turn on, or if you see the BAT indicator on the display, replace the meter’s internal 9-volt battery with a fresh one.
Gb Instruments Gdt-292a User Manual
Tip
Gb Instruments Gdt-292a Manual
Measurements of a 9-volt battery are safe as the voltage is too low to pose a shock hazard.
DC Voltage
Rotate the function selector knob until it points to the 20 range in the DC voltage scale, indicating a maximum of 20 volts. The DC voltage scale is indicated by the V-- symbol on the meter.
Touch the metal tip of the red meter probe to the positive wire of the battery clip; usually this is the red wire. Touch the tip of the black probe to the negative wire, which is black.
Schumacher SE-1250 Manuals & User Guides. User Manuals, Guides and Specifications for your Schumacher SE-1250 Battery Charger. Database contains 3 Schumacher SE-1250 Manuals (available for free online viewing or downloading in PDF): Owner's manual. Schumacher SE-1250 Pdf User Manuals. View online or download Schumacher SE-1250 Owner's Manual. Find the user manual you need for your tools and more at ManualsOnline. Schumacher SE-1250 Battery Charger User Manual. GENERAL BATTERY SAFETY. Before you use your battery charger, be sure to read all. × Sign Up for ManualsOnline. Schumacher owner's manual battery charger se-520ma, se-5212a, se-1275a (13 pages) Battery Charger Schumacher SE-70MA Owner's Manual Fully automatic battery charger 10-amp, 12/24 volt (12 pages). Schumacher battery charger manual.
Read the voltage indicated on the meter’s LCD display. The meter should measure roughly 9 volts.
Tip
You can measure voltage or current with the probe polarity reversed; however, the meter will display a negative number. This does not adversely affect the meter or the components you’re testing.
Warning
G shock ga 110 user manual. Avoid touching the metal probe tips when measuring voltages greater that 50V; high voltages pose a shock hazard.
Resistance
Rotate the function selector knob until it points to the 200 range on the meter’s resistance scale, indicated by the Ω symbol.
Touch the red meter probe tip to one of the resistor’s leads. Touch the black probe to the remaining resistor lead.
Read the resistance on the meter’s display. You should see a reading of about 100 ohms; a few percent higher or lower is normal.
Warning
- Do not touch the metal probe tips when measuring resistance; the resistance of your skin will affect the meter’s accuracy.
- Do not attempt to measure resistance for circuits or components that are powered on or have currents running through them; you might blow the meter’s fuse or damage the unit.
DC Current
Wrap the positive battery clip wire around one of the leads of the resistor.
Rotate the function selector knob until it points to the 200 range in the meter’s DC current scale, indicated by the A-- symbol.
Touch the tip of the red meter probe to the free lead of the resistor. Touch the tip of the black meter probe to the negative battery clip wire.
Read the current value on the meter’s display. You should see a reading of about 90 milliamps or .09 amps.
Warning
Do not attempt to measure currents in excess of 200 milliamps unless the red meter probe is plugged into the 10A DC socket and the selector knob points to the 10A-- range.
Always measure current with a resistance connected in series with a battery or other power source; the resistance limits the current and avoids a potentially damaging short circuit.